Proview® Plus Self Seal Sterilization Pouches, 13" x 18", 200/bx, 1 bx/cs Certol PM1318

Item Number: PM1318
Packaging: cs
Manufacturer: Certol International
Rx
Special Order Item. 14-21 Days Delivery. Item can not be returned.
$186.69

Features & Benefits:

  • Prime Dental Supply offers a broad collection of sterilization pouch to meet Patients need.
  • ProView plus sterilization pouches are convenient self-sealing sterilization packaging constructed with medical grade paper on one side and blue tinted transparent film on the other.
  • Improve process verification with internal and external indicators:
    • Class 4 multi-parameter chemical indicators confirm exposure to steam, temperature and time.
    • Clear consistent color change reinforces verification process.
    • Environmentally responsible - inks are not considered hazardous waste.
  • Medical grade quality maintains sterile contents:
    • Puncture resistant blue laminate film.
    • Super wide self sealing tape seals three ways with special Triple Action Seal™.
    • Tape to paper.
    • Tape to film.
    • Tape to tape.
    • Quick release tape and non-adhesive edge are easier to handle with gloves.
  • Consistent Performance:
    • Extra wide side seals, 36 lbs.
    • high wet strength medical grade paper and five-ply blue poly film protect sterile contents.
    • Industry leading 7/8" self-seal adhesive strip gives users Triple Action Seal™: tape to paper, tape to film and tape to tape.
    • Quality adhesive and materials provide clean peel.
  • User Friendly:
    • Thumb notch and generous knuckle roll area for easy opening.
    • Quick release tape and dry edge enables handling with gloves.
    • Adhesive strip with perforated fold gives complete seal.
  • Design supports aseptic presentation: Clean peel, generous thumb notch and wide knuckle roll area promote aseptic transfer during opening.
  • Versatile: May be used in steam, chemical vapor and ethylene oxide processes.
  • ProView plus sterilization packaging provides dependable quality and verification with Class 4 internal and external chemical indicators.
  • Paper Material: Medical grade, 36# high wet strength kraft.
  • Film Material: Transparent blue tint 5 ply coax polypropylene laminate.
  • Adhesive Strip: 7/8 inch width, with dry edges on release liner for easy removal.
  • Chemical Indicators:
    • Class 4 multi-variable steam indicator with dual placement for both internal and external verification.
    • Ink validated to respond to all three parameters - time, temperature and steam.
    • Indicator ink complies with ISO 11140-1:2005 standard for Class 4 steam indicators.
    • Turns from pink to dark brown/black upon exposure to steam sterilant at 2 minutes and a minimum of 250 degrees F (121 degrees C).
    • Indicators also respond to chemical vapor (pink to light brown) and ethylene oxide gas (green to brown).
  • Product Features and Benefits:
    • Sturdy construction with medical grade materials ensures sterility of contents when handled correctly.
    • Heavy duty paper, 5 ply laminate film and 10 mm width solid rail seal all protect against instrument breakthrough. Super wide adhesive strip design is the maximum width available in self-seal pouch products for ideal security of contents. Solid side seal rails extend to edge to avoid trapping dust. Tack tops prevent curling of plastic film.
    • Chevron at the presentation end assures a smooth, lint-free opening of the package.
  • Use Precautions:
    • ProView plus sterilization pouches are designed for single use only. Load sterilizer according to manufacturer's instructions. Arrange pouches on edge, paper to plastic. Do not overload the chamber.
    • Allow pouch and contents to dry prior to unloading and handling. This product is not recommended for use in dry heat or hydrogen peroxide sterilant processes.
    • According to AAMI ST79 guidelines, clinicians packaging instrument cassettes within self seal pouches may wish to utilize separate internal indicator strips inside the cassette to verify penetration of steam sterilant into the additional mass of instrument cassettes.
    • Certol products ProChek® S and ProChek® ID strips meet this recommendation.
  • Hazardous Waste Information: Independent lab testing verifies that ProView plus pouch inks are not considered hazardous waste and may be disposed of in regular trash.
    • Testing conducted according to EPA procedure 40 CRF 261.24 using the TCLP (Toxicity Characteristic Leaching Procedure, EPA pub. SW-846). Technical Reference available upon request.
  • Pouch Performance: Tested and validated to meet ISO 11607 standard for pouch performance.
  • Available in 13" x 18" Size, Large Cassette Tape.

Application:

  • Designed to securely enclose instruments during steam, chemical vapor or EtO sterilization processing, allow penetration of sterilant, verify exposure to sterilant and maintain sterility during storage.
Show More

FAQs

  • Why are sterilization pouches used?

    Use of sterilization packaging is the proper way to maintain sterility of an item after it has been successfully processed in a sterilizer.

  • How long does sterility last?

    Indefinitely, because sterility is event-related, not time-related. In other words, something has to happen to the packaged item to cause it to become unsterile.

  • What causes items to become unsterile?

    Anything which compromises the package, such as: holes, wetness, broken seals, dropping on floor, dirt or abrasion, etc.

  • Is it appropriate to reuse self-sealing paper/plastic pouches?

    No, steam and heat alter the packaging surface making pin holes more likely during reuse.

  • My pouches are still hot and wet at the end of the steam sterilization process. Is it OK to take them out of the sterilizer and set them on a towel?

    No. Touching a wet pouch will contaminate it and then you will have to repackage it and resterilize it. Microbes can be easily transferred to instruments through wet packaging. Further, during the cooling process, air in the pouch contracts, sucking microbes through the paper. Leave them in the sterilizer until completely cool and dry. Placing them in a pouch rack which holds them on edge during the sterilization process will facilitate both sterilization and drying.

  • What is the best way to maintain asepsis when opening pouches?

    Do not open pouches until immediately prior to use. For surgical procedures, don clean PPE and sterile gloves, use sterile towels to receive items. ProView plus pouches provide a thumb notch and clean peel to aseptically open the pouch without contaminating the contents. Never "punch" instruments through the pouch material.

  • What is the appropriate way to mark on my pouches the date and load number of sterilizations?

    A soft graphite pencil may be carefully used prior to loading the pouch on the paper of the pouch. Indelible marker may be used on the poly side of paper/poly pouches. If indicator tape is used pencil or marker can be used on that. Never use magic marker on the paper side of paper/poly or all paper pouches. The ink may bleed through to the instruments thus contaminating them.

  • Are certain types of packaging required for different types of sterilization processes?

    Yes, for example ProView plus self-sealing paper/plastic pouches are designed for use in steam and chemical vapor sterilization processes. They should not be used in dry heat processes.